6066 (1960-1966) GMC Truck Club Bitcoin now accepted here! 
Pay Dues
Pay Dues or become a Site Supporter
 



Go Back   6066 (1960-1966) GMC Truck Club > 6066 GMC Truck Club Forum > Interiors, Dash, Lights and Electrical
#Sponsored

Interiors, Dash, Lights and Electrical Everything Inside

Reply
 
Thread Tools
  #1  
Old September 22nd, 2013, 04:00 AM
tommyduncan tommyduncan is offline
Senior Member
 
Join Date: Jul 2013
Location: Boulder City NV
Truck: 62 3/4ton 305 Hydramatic
Posts: 189
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 118
tommyduncan is on a distinguished road
Default Diagnosing generator/regulator issues after electrical fire

I had a small electrical fire in the 62 today...

I shut the engine off and heard some sizzling. It was the wires to the ammeter mounted under the dash. I disconnected the battery before it spread... WHEW!

The little hose to the oil pressure gauge next to it melted and it really started smoking!

So I poked around and saw that both wires to the ammeter were fried and so was the ground wire from the generator to the voltage regulator mounting bolt.
The previous owner spliced into the wire from the"bat" terminal on the voltage regulator to the ammeter, and then back from the ammeter to the starter... and didn't use a fuse!
It is hard to tell exactly what happened but I do have some clues:

The burned wire stops where he spliced it near the starter. The rest of that wire appears fine(from the starter to the "bat" terminal of the ignition switch I'm thinking?).

The middle contact in the voltage regulator barely opens(I mean a frogs hair). The inside of the voltage regulator doesn't smell burned in any way though....

At idle the "gen" idiot light wouldn't completely go out and the ammeter would read 0 or just above 0. Give it gas and it would move though.

There has been a faint grinding noise under the hood from the same side as the generator. I didn't think it was the generator though since it has been working fine...

I can fix the wiring easy enough. I am afraid of something in the generator or the voltage regulator being a problem? I also forgot to polarize it when I put the battery in a couple weeks ago. Could that cause the wires to melt?
Is there a way to test these components individually?
Do ammeters fail and cause these problems? If I dare hook it up again it will be with a 30 amp fuse!

Last edited by tommyduncan; September 22nd, 2013 at 04:31 AM.
Reply With Quote
  #2  
Old September 22nd, 2013, 08:35 PM
tommyduncan tommyduncan is offline
Senior Member
 
Join Date: Jul 2013
Location: Boulder City NV
Truck: 62 3/4ton 305 Hydramatic
Posts: 189
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 118
tommyduncan is on a distinguished road
Default Re: Diagnosing generator/regulator issues after electrical fire

My 2 spare motors came with a lotta spare parts, including a generator and an alternator.When I first got them I held the alternator and upper bracket up to the block and it didn't seem like it went to these motors. I thought the only lower bracket was for a generator.
Since I need to do some wiring I decided to upgrade to an alternator. The one that came with the motors was externally regulated. Not what I want but it is what came on these motors so I took a closer look. The lower mount was bolted to one of the engines!
I dunno how I missed that but good for me!

Then I peeked under the hood of my 63 Chevy...

It had a 10si!

Now I just need some hardware, a belt, and some time with a soldering gun and I will be set!
Reply With Quote
  #3  
Old September 23rd, 2013, 07:08 PM
FetchMeAPepsi's Avatar
FetchMeAPepsi FetchMeAPepsi is offline
-= Dues Paid =-
 
Join Date: Jan 2013
Location: Edmond, Ks
Truck: 1962 4x4 GMC CECILIA
Posts: 1,783
Thanks: 22
Thanked 6 Times in 5 Posts
Rep Power: 570
FetchMeAPepsi is a glorious beacon of lightFetchMeAPepsi is a glorious beacon of lightFetchMeAPepsi is a glorious beacon of lightFetchMeAPepsi is a glorious beacon of lightFetchMeAPepsi is a glorious beacon of lightFetchMeAPepsi is a glorious beacon of light
Default Re: Diagnosing generator/regulator issues after electrical fire

That was kinda scary Tommy!

I wish I had info on generators to give you a hand. I kinda like the idea of using one, but my truck came with a 17SI that I just rebuilt so I never got to play with a generator.

Fun fact: You can remove a battery from a generator truck and it'll still run! You can't do that with an alternator. Great for battery sharing if you're too cheap to buy two. You'll like the 10SI though. They're troublefree and easy as pie to rebuild for about 16 bucks!
__________________
Step by steps:

To view links or images in signatures your post count must be 0 or greater. You currently have 0 posts.


To view links or images in signatures your post count must be 0 or greater. You currently have 0 posts.


To view links or images in signatures your post count must be 0 or greater. You currently have 0 posts.

Some people are like slinkys. Not worth much but funny as heck when pushed down stairs.
__________________
If the women don't find you handsome, they should at least find you handy.
Reply With Quote
  #4  
Old September 23rd, 2013, 07:24 PM
tommyduncan tommyduncan is offline
Senior Member
 
Join Date: Jul 2013
Location: Boulder City NV
Truck: 62 3/4ton 305 Hydramatic
Posts: 189
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 118
tommyduncan is on a distinguished road
Default Re: Diagnosing generator/regulator issues after electrical fire

I ran a later model Jeep without a battery. It wouldn't idle (I think because of the TPS sensor) but it ran fine for a few minutes with my foot on the gas... I have since been told that is a no no.
The 10si should be fine but I eventually have to put something back in the other truck so I might as well get a 12si for this one since it is wired the same. I want to do a little modernizing while I'm at it... relays for the headlights, fusible links, etc...

...and removal of the evil ammeter. I'm reasonably sure that the fire started there
Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
RE: [6066 GMC] Generator/Regulator Archiver Previous Forum Posts 0 December 30th, 2004 03:10 AM
Re: [6066 GMC] Generator/Regulator Archiver Previous Forum Posts 0 December 30th, 2004 02:08 AM
Re: [6066 GMC] Generator/Regulator Archiver Previous Forum Posts 0 December 29th, 2004 01:55 AM
RE: [6066 GMC] Generator/Regulator Archiver Previous Forum Posts 0 December 28th, 2004 01:21 AM
Generator/Regulator Archiver Previous Forum Posts 0 December 24th, 2004 01:12 AM


All times are GMT +1. The time now is 04:13 PM.


Powered by vBulletin® Version 3.8.7
Copyright ©2000 - 2013, Jelsoft Enterprises Ltd 911731456399|1730387594|0